api_key: "{{ modane_server_thermostat_api_key }}"
|
||
|
|
||
|
debug: False
|
||
|
|
||
|
targets:
|
||
|
- target_awake_temperature
|
||
|
- target_sleep_temperature
|
||
|
- target_frost_protection
|
||
|
|
||
|
modes:
|
||
|
- short_absence
|
||
|
- long_absence
|
||
|
|
||
|
rooms_settings:
|
||
|
"double bedroom":
|
||
|
target_awake_temperature: 19
|
||
|
target_unconfirmed_awake_temperature: 18
|
||
|
target_sleep_temperature: 18
|
||
|
target_unconfirmed_sleep_temperature: 18
|
||
|
target_frost_protection: 6
|
||
|
metric: Modane_temperature_double_bedroom
|
||
|
relays: "1"
|
||
|
enabled: True
|
||
|
"single bedroom":
|
||
|
target_awake_temperature: 17
|
||
|
target_unconfirmed_awake_temperature: 16
|
||
|
target_sleep_temperature: 16
|
||
|
target_unconfirmed_sleep_temperature: 16
|
||
|
target_frost_protection: 6
|
||
|
metric: Modane_temperature_single_bedroom
|
||
|
relays: "3"
|
||
|
enabled: True
|
||
|
"living room":
|
||
|
target_awake_temperature: 21
|
||
|
target_unconfirmed_awake_temperature: 21
|
||
|
target_sleep_temperature: 18
|
||
|
target_unconfirmed_sleep_temperature: 18
|
||
|
target_frost_protection: 6
|
||
|
metric: Modane_temperature_living_room
|
||
|
relays: "4"
|
||
|
enabled: True
|
||
|
"bathroom":
|
||
|
target_awake_temperature: 21
|
||
|
target_unconfirmed_awake_temperature: 21
|
||
|
target_sleep_temperature: 19
|
||
|
target_unconfirmed_sleep_temperature: 19
|
||
|
target_frost_protection: 6
|
||
|
metric: Modane_temperature_bathroom
|
||
|
relays: ""
|
||
|
enabled: False
|
||
|
|
||
|
# If there is too much load, it most likely means someone is cooking and nobody is in the bedrooms.
|
||
|
shedding_order:
|
||
|
- double bedroom
|
||
|
- single bedroom
|
||
|
- living room
|
||
|
|
||
|
default_target: target_frost_protection
|
||
|
|
||
|
# Load in VA
|
||
|
relays_load:
|
||
|
"1": 1500
|
||
|
"3": 1500
|
||
|
"4": 2000
|
||
|
|
||
|
awake_hour: "7:30"
|
||
|
sleep_hour: "23:30"
|
||
|
forced_mode_duration: 7200.0
|
||
|
load_shedder_interval: 10.0
|
||
|
relay_control_interval: 300.0
|
||
|
hysteresis: 0.5
|
||
|
|
||
|
# Puissance souscrite : 6kVA
|
||
|
# Puissance max avant coupure (marge 30%) : 7,8kVA
|
||
|
max_load: 7800
|
||
|
load_margin: 100
|
||
|
|