api_key: "{{ modane_server_thermostat_api_key }}" debug: False targets: - target_awake_temperature - target_sleep_temperature - target_frost_protection modes: - short_absence - long_absence rooms_settings: "double bedroom": target_awake_temperature: 19 target_unconfirmed_awake_temperature: 18 target_sleep_temperature: 18 target_unconfirmed_sleep_temperature: 18 target_frost_protection: 6 metric: Modane_temperature_double_bedroom relays: "1" enabled: True "single bedroom": target_awake_temperature: 17 target_unconfirmed_awake_temperature: 16 target_sleep_temperature: 16 target_unconfirmed_sleep_temperature: 16 target_frost_protection: 6 metric: Modane_temperature_single_bedroom relays: "3" enabled: True "living room": target_awake_temperature: 21 target_unconfirmed_awake_temperature: 21 target_sleep_temperature: 18 target_unconfirmed_sleep_temperature: 18 target_frost_protection: 6 metric: Modane_temperature_living_room relays: "4" enabled: True "bathroom": target_awake_temperature: 21 target_unconfirmed_awake_temperature: 21 target_sleep_temperature: 19 target_unconfirmed_sleep_temperature: 19 target_frost_protection: 6 metric: Modane_temperature_bathroom relays: "" enabled: False # If there is too much load, it most likely means someone is cooking and nobody is in the bedrooms. shedding_order: - double bedroom - single bedroom - living room default_target: target_frost_protection # Load in VA relays_load: "1": 1500 "3": 1500 "4": 2000 awake_hour: "7:30" sleep_hour: "23:30" forced_mode_duration: 7200.0 load_shedder_interval: 10.0 relay_control_interval: 300.0 hysteresis: 0.5 # Puissance souscrite : 6kVA # Puissance max avant coupure (marge 30%) : 7,8kVA max_load: 7800 load_margin: 100